Restaurant · 01 Restaurant ventilation is two jobs under one roof: pull heat and grease off the line, keep the dining room comfortable without kitchen smell. Aurum Prodest designs canopy extract, make-up air and a separate dining circuit so guests do not eat in the kitchen airstream.
An undersized hood leaves smoke over the fryer; an oversized hood without make-up air slams doors and starves gas appliances. We size extract from the actual line — wok, grill, oven, pass — each with its own duty. Grease filters and a grease trap belong in the first drawing, or ducts cake in a season.
An undersized hood leaves smoke over the fryer; an oversized hood without make-up air slams doors and starves gas appliances. We size extract from the actual line — wok, grill, oven, pass — each with its own duty. Grease filters and a grease trap belong in the first drawing, or ducts cake in a season.
Make-up air is mandatory: 80–90% of extract volume is supplied on purpose so the room does not steal air from toilets and the dining room. Dining air is 20–60 m³/h per guest depending on density. Kitchen grease never shares the dining AHU.
Hot extract ducts are steel with wash access, slope and drain points. Flexible duct on a kitchen extract is a fire and odour problem. Fire dampers and spark arrestors follow hot-line rules. Roof and façade penetrations are agreed before fit-out so the signage is not rebuilt.
Dining noise must not include the kitchen fan. The fan sits on the roof or in a plant room with a silencer. Shisha, bakery and pastry lines get extra local extract. Live restaurants are fitted at night with a kitchen-down plan agreed in advance.
Commissioning measures canopy and dining flows, interlocks extract with cooking equipment, and trains staff on filter washing. 5-year workmanship warranty. Grease-trap and duct wash stay on a calendar or the fan “loses power” regardless of motor size.
Office ventilation is sized from headcount, equipment heat and working hours — not from floor area slogans.
Workshop ventilation is sized from process emissions, not from floor-area myths.
Warehouse ventilation protects goods and people, not “air under the ridge for its own sake”.
Supply-exhaust ventilation is not “two fans at opposite ends of the building”. It is a balanced AHU: what you take from outside you throw away, filtered, heated, often with heat recovery. Aurum Prodest selects supply-only, extract-only o…
Ventilation design saves site rework: air change and pressure first, then duct sizes and purchase lists.
Ventilation succeeds on airflow design and ducts more than brand stars. Pros/cons of units we install often.
A brief comparison by class and use case — we match equipment to budget and site
Swipe the table sideways →
| Brand | Class | Pros | Cons |
|---|---|---|---|
| | Mid-range | Predictable AHU selection and kits | Pricier than pure value brands |
| | Mid-range | European mid for offices and F&B | Not the cheapest entry |
| | Mid-range | Quality fans, long life | Narrower “boxed AHU” range |
| | Mid-range | Central units for large networks | Heavier specs and cost |
| | Best value | Best value for typical networks | Less premium build reserve |
| | Best value | Accessible AHUs and light-commercial kits | Weaker mid on heavy industrial duty |
| Kitchen make-up | 80–90% of extract |
|---|---|
| Dining | 20–60 m³/h per guest |
| Hot ducts | steel, washable |
| Canopy filters | grease, wash on schedule |
| Live café install | night shifts |
| Work warranty | 5 years |
Grease, heat and odour need a dedicated extract. An office AHU on a hot line becomes a fire and hygiene problem.
Usually yes: sparks, extra flow, often a dedicated fan. One “catch-all” hood rarely works.
Missing make-up air, pressure imbalance, or WC extract weaker than the kitchen. We measure pressures before replacing everything.
A small café with a ready plant room — sometimes. A full hot line depends on roof works. Real dates follow the survey.
As-built drawings, equipment passports, airflow reports. Official sanitary papers are the client’s; we supply the technical base.
Staff wash canopy filters on the schedule. Ducts and traps — service crew, typically every 1–3 months depending on the menu.
Ventilation installation — 12 cities. Crew dispatch, contract, warranty.
Capital · 500+ projects
Learn moreTourism capital · Hotels & malls
Learn moreAncient city · Heat up to +45°C
Learn moreFergana industrial center
Learn moreFergana Valley business hub
Learn moreRegional center · Healthcare & education
Learn moreKarakalpakstan · Extreme climate
Learn moreKhorezm · Trade & tourism
Learn moreOil & gas · Industrial facilities
Learn moreAgrarian region · Construction growth
Learn moreHottest city · Up to +50°C
Learn moreMining center · Energy sector
Learn more