Cooling coils · 10 AHU cooling coils take heat off outdoor air: chilled water or DX from a condensing unit. Aurum Prodest sizes the section, fits an eliminator and drain, and keeps condensate out of the duct and finished ceiling.
40 °C outdoor air without a coil stuffs an office even with splits — you cool the same hot air. An AHU coil unloads room units and keeps air-change hygiene. We size flow and ΔT and tie to a chiller or condensing unit.
40 °C outdoor air without a coil stuffs an office even with splits — you cool the same hot air. An AHU coil unloads room units and keeps air-change hygiene. We size flow and ΔT and tie to a chiller or condensing unit.
Eliminator and drain are not optional. Skip them and you get wet ducts, mould, inspection trouble. Fall, trap, clean-out. Insulate the cold run after the coil against outer condensate.
DX: braze, vacuum, match the outdoor CU. Water: valves and balance with FCUs on the same chiller so the AHU does not steal the building’s cooling.
This is air treatment in the unit, not cooling one room. We do not sell a coil as a substitute for a shop split.
Commission supply temperature and no droplet carry-over. Service: coil wash, tray. Factory and workmanship by contract.
HVAC exchangers join circuits with different fluids: water-water, steam-water, glycol.
Heating coils warm outdoor air. Aurum Prodest sizes water and electric coils on airflow and heating-water schedule, fits freeze protection and does not let the unit ice on the first January night shift.
Coils and heat exchangers: sizing first, brand second. Pros/cons cover durability, hydraulics, and kit completeness.
A brief comparison by class and use case — we match equipment to budget and site
Swipe the table sideways →
| Brand | Class | Pros | Cons |
|---|---|---|---|
| | Premium | One ecosystem with manufacturer systems | Costlier than universal coils |
| | Premium | Premium heat exchange for industrial loops | High price and lead times |
| | Premium | Precise plate HEX selection | Premium budget per unit |
| | Mid-range | Clear ratings and familiar hydraulics | Not always best efficiency/$ |
| | Mid-range | Easy match to same-brand AHUs | Narrower than pure heat specialists |
| | Mid-range | Rotary recovery for efficient AHUs | Niche vs full HVAC brands |
| Eliminator | required |
|---|---|
| Drain | fall, trap, clean-out |
| Water | balance with FCUs |
| DX | CU + vacuum |
| Insulation | after the section |
| Not a substitute | for a room split |
Untreated outdoor air is hot air into the room. Splits wear out. You often need both.
No eliminator, drain or insulation. Find the node, not “a bad unit”.
Chiller — water. No chiller — CU. We count power and service.
If space and board allow. Sometimes a new unit is cheaper.
Dry networks and filters help. A wet duct does the opposite.
Yes — a water coil is fed by that cooling.
Thermal equipment — 12 cities. Crew dispatch, contract, warranty.
Capital · 500+ projects
Learn moreTourism capital · Hotels & malls
Learn moreAncient city · Heat up to +45°C
Learn moreFergana industrial center
Learn moreFergana Valley business hub
Learn moreRegional center · Healthcare & education
Learn moreKarakalpakstan · Extreme climate
Learn moreKhorezm · Trade & tourism
Learn moreOil & gas · Industrial facilities
Learn moreAgrarian region · Construction growth
Learn moreHottest city · Up to +50°C
Learn moreMining center · Energy sector
Learn more