Heat exchangers, heating coils, cooling coils, and thermal transfer equipment — supplied, installed, and integrated into your HVAC system by Aurum Prodest. We size every component for your heat transfer fluid, air volume, and temperature differential so the system performs at design conditions, not just on paper.

Nukus sits in one of Uzbekistan's harshest climate bands: winter nights near −25°C and summer afternoons above +45°C demand equipment with a wide operating envelope — not entry-level splits. Aurum Prodest specifies low-temperature heat pumps, frost-proof outdoor units, and heavily insulated refrigerant lines for year-round comfort in apartments, schools, and government buildings. Heating via inverter heat pump often costs less than electric radiators when sized correctly.

Equipment selection depends on whether your system uses water, glycol, steam, or refrigerant as the heat transfer medium. We match coil face area, row depth, and fin spacing to the required duty and available pressure drop in both air and fluid circuits.

  • Heat exchanger and coil sizing
  • Water and refrigerant circuit design
  • Equipment supply and delivery
Government institutionsResidential buildingsRetail propertiesOffices
Thermal equipment in Nukus Nukus · 09

By the numbers

12+ years on market
500+ projects delivered
50+ specialists
5yr warranty

About the service

Equipment selection depends on whether your system uses water, glycol, steam, or refrigerant as the heat transfer medium. We match coil face area, row depth, and fin spacing to the required duty and available pressure drop in both air and fluid circuits.

Water coils connect to boiler loops, chiller circuits, or district heating supplies. Refrigerant coils integrate with DX systems and heat pumps. Each connection is designed for proper flow distribution, venting, and future maintenance access.

Before start-up we perform hydraulic pressure tests, check for leaks at every joint and gasket, and insulate bare pipework to prevent condensation and energy loss. Coil banks are installed with adequate drainage slope for condensate removal.

Commissioning verifies that supply air temperatures meet specification across the operating range. We connect coils to air handling unit automation — enabling frost protection, staging, and temperature control sequences that protect equipment and maintain comfort.

Our experience in Nukus

Karakalpakstan's continental swing destroys generic hardware: compressors starve in cold, capacitors fail in heat. We deploy Daikin Altherma-class and Mitsubishi Zubadan-type solutions where heating below −15°C is required, and high-ambient cooling lines for July dust storms.

Public buildings and housing near Berdaq Avenue and the museum district need reliable systems with simple maintenance — filters reachable without scaffolding, outdoor units protected from wind-blown sand. We elevate condensers, use anti-corrosion coats, and plan defrost cycles for winter mornings.

Retail and small offices along Kungrad road depend on fast response when a system fails in a heatwave. Aurum Prodest dispatches from Tashkent with pre-diagnosed parts when possible, and offers preventive service each autumn and spring to catch weakened charge or brittle insulation.

Service areas in Nukus

  • Berdaq Avenue
  • A. Dosov district
  • Karakalpakstan Museum area
  • Birlestik
  • Kungrad road corridor
  • Telex center
  • Akbulak
  • Chimbay road junction
  • New residential blocks
  • Market (bazaar) zone

Why clients choose us in Nukus

  • Heat pumps rated for heating well below −15°C
  • High-ambient cooling for +45°C summers
  • Sand and frost protection on outdoor equipment
  • All-season commissioning — winter and summer tests
  • Regional dispatch from Tashkent with planned logistics

What's included

  • 01 Heat exchanger and coil sizing
  • 02 Water and refrigerant circuit design
  • 03 Equipment supply and delivery
  • 04 Installation in AHUs and duct sections
  • 05 Piping, valving, and insulation
  • 06 Hydraulic pressure and leak testing
  • 07 Automation and control integration
  • 08 Scheduled maintenance and coil cleaning

How we work

  1. 01 Thermal duty and airflow calculation
  2. 02 Equipment specification and ordering
  3. 03 Delivery and mechanical installation
  4. 04 Piping connection and insulation
  5. 05 Pressure testing and commissioning
  6. 06 Performance verification and handover

Advantages

Experienced specialists
Work warranty
Certified equipment
Same-day site visit
Transparent pricing
In-house production

Questions about Nukus

What systems work at −25°C frost in Nukus?

Low-temperature inverter heat pumps with dedicated cold-climate kits — such as Daikin Altherma or Mitsubishi Electric Zubadan lines — maintain heating down to roughly −25°C to −30°C depending on model. Standard cooling-only splits are not sufficient as primary heat.

Can an air conditioner be used for heating in winter?

Yes, if it is an inverter heat-pump model within its low-ambient heating range. We calculate balance point against local design temperature and add auxiliary heat only when the physics require it.

How do you protect equipment from desert dust?

Filter screens, more frequent service intervals, sealed electrical boxes, and raised mounting reduce sand ingress. Indoor pre-filters are upgraded where PM levels spike in spring.

What is the lead time for installation in Nukus?

After contract and equipment availability confirmation, crews typically arrive within three to five business days from Tashkent. Winter installs are planned around temperature windows for brazing and pressure testing.

Do you warranty work in Karakalpakstan the same as in Tashkent?

Yes — five years on Aurum Prodest installation workmanship plus manufacturer equipment warranty. Service calls are scheduled through our central office with regional visit batches.

Need a consultation in Nukus? We respond within 15 minutes. Engineer visit and site survey are free when you sign a contract.