Chiller · 07 A chiller–fan coil system cools with water: one chiller on the roof or yard, fan coils in the rooms. Aurum Prodest designs the hydraulics, installs the pump set and commissions so distant coils are not warm in July.
A chiller without hydraulics is a noisy box. We size water flow, pipe losses, three-port valves and balancing. Tashkent condensers get outdoor-temperature margin. Glycol only if the circuit can freeze; extra glycol just hurts heat transfer.
A chiller without hydraulics is a noisy box. We size water flow, pipe losses, three-port valves and balancing. Tashkent condensers get outdoor-temperature margin. Glycol only if the circuit can freeze; extra glycol just hurts heat transfer.
Pump set: duty plus standby, strainer, expansion vessel, gauges you can read. Chiller pipework with flex connectors and compressor-change space. Fan coils are selected for office noise or ducted static.
Controls hold zone temperature without one-minute cycling. BMS is optional for malls and offices. AHU coils on the same chilled water when the design says so.
Pipes get slopes, vents, insulation against attic condensate. Ducts to ducted FCUs come from our shop. Commissioning: flush, fill, de-aerate, valve set, flow reports.
Service: pressures, condenser wash, oil and controls. 5-year workmanship; equipment per manufacturer if start-up rules were kept.
Industrial air-conditioning design starts with a survey, not a chiller brochure.
A central system treats air in one machine — AHU or chamber — and ducts it through the building.
Industrial air conditioning holds process and people temperature, not “home comfort in a shed”.
In industry, class equals downtime risk and ownership cost. Pros/cons by segment for plant, warehouse, or mall.
A brief comparison by class and use case — we match equipment to budget and site
Swipe the table sideways →
| Brand | Class | Pros | Cons |
|---|---|---|---|
| | Premium | Range scale and large-plant experience | High ownership cost at entry |
| | Premium | Reliability in continuous duty | Expensive for non-critical zones |
| | Premium | Industrial premium chillers/central plant | Long leads and strict budgets |
| | Mid-range | Capacity + standards + workable quote | Not always top for comfort noise |
| | Mid-range | Typical industrial loads | Less premium line flexibility |
| | Mid-range | Common CIS commercial pick | Depends on local support |
| | Mid-range | Handy in an AHU package | Not the #1 “heavy chiller” brand |
| Fluid | water / mix by climate |
|---|---|
| Pumps | duty + standby |
| Balancing | valves on branches |
| Heat | condenser for Tashkent peak |
| Start-up | flush + reports |
| Work warranty | 5 years |
Fewer outdoor units, one plant, zone control. Hydraulics must be calculated, not guessed.
Only after load and frame check. Otherwise you punch the roof — not a brand issue.
Not always. Outdoor freeze risk — yes. A warm plant room often runs water with control protection.
Not acceptable. We pick low-noise units and network static. The cheapest ducted unit is always audible in a meeting room.
Weeks on a small office building to months on a mall. Chiller lead time and power are the usual gates.
Yes, after survey. Not every circuit can be “just topped up” without a flush.
Industrial air conditioners — 12 cities. Crew dispatch, contract, warranty.
Capital · 500+ projects
Learn moreTourism capital · Hotels & malls
Learn moreAncient city · Heat up to +45°C
Learn moreFergana industrial center
Learn moreFergana Valley business hub
Learn moreRegional center · Healthcare & education
Learn moreKarakalpakstan · Extreme climate
Learn moreKhorezm · Trade & tourism
Learn moreOil & gas · Industrial facilities
Learn moreAgrarian region · Construction growth
Learn moreHottest city · Up to +50°C
Learn moreMining center · Energy sector
Learn more